Heat Transfer
Conduction, convection, radiation, and heat exchanger design.
Introduction to Heat Transfer Modes
What is Heat Transfer? Heat transfer is the study of energy movement due to temperature differences. It's distinct from thermodynamics: thermodynamics tells us whether a process is possible; heat...
What is Heat Transfer?
Heat transfer is the study of energy movement due to temperature differences. It's distinct from thermodynamics: thermodynamics tells us whether a process is possible; heat transfer tells us how fast it happens.
Three modes:
- Conduction: through solids or stationary fluids
- Convection: between a surface and a moving fluid
- Radiation: electromagnetic waves, no medium needed
Conduction — Fourier's Law
q = -k × A × dT/dx
where q is the heat rate (W), k is thermal conductivity (W/m·K), A is area (m²), and dT/dx is the temperature gradient.
For a plane wall of thickness L:
q = k × A × (T₁ - T₂) / L
Thermal resistance:
R_cond = L / (k × A)
Thermal Conductivity
| Material | k (W/m·K) |
|----------|-----------|
| Air | 0.026 |
| Foam | 0.03 |
| Water | 0.6 |
| Glass | 1.0 |
| Stainless steel | 16 |
| Aluminum | 205 |
| Copper | 385 |
| Diamond | 2000 |
The huge range (5 orders of magnitude) explains why insulation works so well and why heat sinks are made of aluminum or copper.
Convection — Newton's Law of Cooling
q = h × A × (T_s - T_∞)
where h is the convection heat transfer coefficient (W/m²·K):
- Natural convection (air): 5-25
- Forced convection (air): 25-250
- Natural convection (water): 20-100
- Forced convection (water): 500-10,000
- Boiling: 3,000-100,000
- Condensation: 5,000-100,000
Convective thermal resistance:
R_conv = 1 / (h × A)
Radiation — Stefan-Boltzmann
q = ε × σ × A × (T_s⁴ - T_surr⁴)
where ε is emissivity (0-1), σ = 5.67 × 10⁻⁸ W/m²·K⁴.
For small temperature differences, we can linearize:
q ≈ h_r × A × (T_s - T_surr)
where h_r = 4εσT_m³ is the radiative heat transfer coefficient.
At room temperature, h_r ≈ 6 W/m²·K for ε = 1. So radiation is comparable to natural convection at room temperature.
Combined Heat Transfer
Real systems often have all three modes simultaneously. Use thermal resistance networks:
R_total = R_conv1 + R_cond + R_conv2
For a composite wall with N layers:
R_total = Σ (L_i / k_i A) + 1/(h₁A) + 1/(h₂A)
Heat rate:
q = ΔT / R_total
Overall Heat Transfer Coefficient
For a wall separating two fluids:
q = U × A × ΔT
where U is the overall coefficient:
1/U = 1/h₁ + Σ(L_i/k_i) + 1/h₂
U values:
- Single glass window: U = 5.7 W/m²·K
- Double glazed: U = 2.8 W/m²·K
- Well-insulated wall: U = 0.3 W/m²·K
- Vacuum flask: U < 0.05
Key Takeaways
- Three modes: conduction, convection, radiation
- Fourier: q = -kA dT/dx
- Newton: q = hA(T_s - T_∞)
- Stefan-Boltzmann: q = εσA(T_s⁴ - T_surr⁴)
- Thermal resistance networks combine modes
- U-value summarizes overall heat transfer
Steady-State Conduction
The Heat Diffusion Equation The general equation for conduction: ∂/∂x (k ∂T/∂x) + ∂/∂y (k ∂T/∂y) + ∂/∂z (k ∂T/∂z) + q_gen = ρ Cp ∂T/∂t For 1D, steady, no generation: d/dx (k dT/dx) = 0 For con...
The Heat Diffusion Equation
The general equation for conduction:
∂/∂x (k ∂T/∂x) + ∂/∂y (k ∂T/∂y) + ∂/∂z (k ∂T/∂z) + q_gen = ρ Cp ∂T/∂t
For 1D, steady, no generation:
d/dx (k dT/dx) = 0
For constant k:
d²T/dx² = 0
Solution: T(x) is linear in a plane wall.
Plane Wall
Temperature profile: T(x) = T₁ + (T₂ - T₁) × x/L
Heat rate: q = kA(T₁ - T₂)/L
Constant heat rate through the wall.
Cylindrical Wall (Pipe Insulation)
For a cylinder of inner radius r₁ and outer radius r₂:
q = 2πkL(T₁ - T₂) / ln(r₂/r₁)
Thermal resistance:
R = ln(r₂/r₁) / (2πkL)
The critical radius of insulation:
r_cr = k / h
Adding insulation increases heat loss until r = r_cr, then decreases. For thin wires, adding a small amount of insulation can actually increase heat loss.
Spherical Shell
q = 4πk(T₁ - T₂) / (1/r₁ - 1/r₂)
Used for spherical tanks and spheres of insulating material.
Composite Walls
For N layers in series:
q = (T₁ - T_{N+1}) / Σ R_i
where R_i = L_i / (k_i A).
Interface temperatures are found by working through the resistances.
Contact Resistance
Real surfaces have microscopic roughness, creating an interface resistance:
R_contact = 1 / (h_c A)
where h_c is the contact conductance (W/m²·K). Typical values:
- Metal-metal, smooth, high pressure: 10,000-30,000
- Metal-metal, rough, low pressure: 1,000-5,000
- With thermal paste: 5,000-20,000
- With air gap: 100-1,000
This matters for electronics cooling — a bad CPU-heatsink interface can dominate thermal resistance.
Extended Surfaces (Fins)
Fins increase surface area for convective heat transfer. Common types:
- Straight fins (rectangular cross-section)
- Pin fins (circular)
- Annular fins (around pipes)
Fin efficiency:
η_fin = actual heat transfer / maximum possible (if entire fin at base temperature)
For a straight fin with adiabatic tip:
η_fin = tanh(mL) / (mL)
where m = √(hP/(kA_c)).
Overall surface efficiency:
η_o = 1 - (A_fin/A_total) × (1 - η_fin)
Fin effectiveness:
ε_fin = q_fin / (h A_c θ_b)
Effective fins have ε > 2. For ε < 2, the fin isn't worth the cost.
Applications
- Heat sinks for electronics (aluminum fins)
- Radiators in cars
- Fins on air-cooled engines
- Heat exchanger tubes (often finned on the air side)
Key Takeaways
- 1D steady conduction: T is linear in a plane wall, logarithmic in a cylinder
- Composite walls: resistances add
- Contact resistance is often the bottleneck
- Fins increase surface area; efficiency depends on geometry
- Critical radius of insulation for cylinders
- Fin effectiveness must exceed 2 for a fin to be worthwhile
Convection Fundamentals
The Convection Coefficient Convection depends on: Fluid properties (k, μ, Cp, ρ) Flow velocity Surface geometry Whether flow is laminar or turbulent Whether it's natural or forced The...
The Convection Coefficient
Convection depends on:
- Fluid properties (k, μ, Cp, ρ)
- Flow velocity
- Surface geometry
- Whether flow is laminar or turbulent
- Whether it's natural or forced
The convection coefficient h bundles all of this. Typical values range from 5 to 100,000 W/m²·K — a huge range.
The Nusselt Number
Dimensionless heat transfer coefficient:
Nu = h × L / k_fluid
Nu = 1 means pure conduction; Nu >> 1 means convection dominates.
For a flat plate in laminar flow:
Nu = 0.332 × Re^0.5 × Pr^(1/3)
For turbulent:
Nu = 0.037 × Re^0.8 × Pr^(1/3)
Reynolds and Prandtl Numbers
Re = ρVL/μ characterizes flow regime.
Pr = μCp/k = ν/α characterizes the fluid:
- Liquid metals: Pr << 1
- Gases: Pr ≈ 0.7
- Water: Pr ≈ 7
- Oils: Pr >> 100
External Flow over a Flat Plate
Laminar boundary layer until Re_x = 5 × 10⁵. Then transition to turbulent.
Local Nusselt number:
Laminar: Nu_x = 0.332 Re_x^0.5 Pr^(1/3)
Turbulent: Nu_x = 0.0296 Re_x^0.8 Pr^(1/3)
Average Nusselt number over a plate of length L:
Laminar: Nu_L = 0.664 Re_L^0.5 Pr^(1/3)
Turbulent: Nu_L = 0.037 Re_L^0.8 Pr^(1/3)
Flow over Cylinders and Spheres
The Churchill-Bernstein correlation covers a wide Re range for cylinders:
Nu_D = 0.3 + 0.62 Re^0.5 Pr^(1/3) / [1 + (0.4/Pr)^(2/3)]^0.25 × [1 + (Re/282000)^0.625]^0.8
For spheres, the Whitaker correlation is standard.
Internal Flow (Pipe Flow)
Entry length: L_e/D ≈ 0.05 Re (laminar), 10 (turbulent).
For laminar fully developed flow:
Nu_D = 3.66 (constant wall temperature)
Nu_D = 4.36 (constant heat flux)
For turbulent (Dittus-Boelter):
Nu_D = 0.023 Re^0.8 Pr^n
where n = 0.4 for heating, 0.3 for cooling
Natural Convection
When buoyancy drives flow, use:
Nu = C × Ra^n
where Ra = Gr × Pr is the Rayleigh number:
Gr = g β ΔT L³ / ν² (Grashof number)
Typical for a vertical plate:
Laminar (10⁴ < Ra < 10⁹): Nu = 0.59 Ra^0.25
Turbulent (Ra > 10⁹): Nu = 0.13 Ra^(1/3)
Natural convection gives much lower h than forced. Air-cooled heat sinks rely on natural convection, so they need to be large.
Boiling and Condensation
Boiling has different regimes:
- Nucleate boiling: bubbles form at nucleation sites, very high h
- Transition boiling: unstable, h decreases
- Film boiling: vapor blanket, low h (this is why quenching in water works — the film boiling phase cools slowly)
Condensation:
- Filmwise: liquid film on surface, moderate h
- Dropwise: droplets form and fall off, much higher h (10× filmwise)
Key Takeaways
- Convection coefficient h is the key unknown
- Nusselt number relates h to k
- Correlations exist for common geometries
- Laminar vs turbulent matters (different Nu formulas)
- Natural convection gives lower h than forced
- Boiling and condensation have extremely high h
- Always check which correlation applies to your case
Radiation Heat Transfer
The Nature of Radiation All objects emit electromagnetic radiation. The intensity and spectrum depend on temperature. Thermal radiation is in the infrared (wavelength 0.1-100 µm) for room-temperature...
The Nature of Radiation
All objects emit electromagnetic radiation. The intensity and spectrum depend on temperature.
Thermal radiation is in the infrared (wavelength 0.1-100 µm) for room-temperature objects, and extends into visible for very hot objects (like the sun).
Blackbody Radiation
A blackbody absorbs all incident radiation. Its emission is described by:
Planck's law (spectral distribution):
E_λb = (2πhc² / λ⁵) × 1 / (e^(hc/λkT) - 1)
Wien's displacement law (peak wavelength):
λ_max = 2898 / T (µm, with T in K)
At T = 3000 K, λ_max = 0.97 µm (infrared, near-visible).
Stefan-Boltzmann law (total emission):
E_b = σ T⁴
where σ = 5.67 × 10⁻⁸ W/m²·K⁴.
Real Surfaces
Real surfaces emit less than a blackbody. The ratio is emissivity ε:
E = ε × σ × T⁴
Emissivity ranges:
- Polished aluminum: ε = 0.05
- Oxidized aluminum: ε = 0.3
- White paint: ε = 0.9
- Black paint: ε = 0.95
- Human skin: ε = 0.98
High-emissivity surfaces radiate well; low-emissivity surfaces (like polished metal) do not. This is why silvered surfaces are used in vacuum flasks.
Absorptivity, Reflectivity, Transmissivity
Incident radiation is distributed among:
- Absorptivity α (absorbed)
- Reflectivity ρ (reflected)
- Transmissivity τ (transmitted)
α + ρ + τ = 1
For opaque surfaces, τ = 0, so α + ρ = 1.
Kirchhoff's law: for a surface in thermal equilibrium, α = ε at each wavelength. Good absorbers are good emitters.
View Factors
Radiative exchange between surfaces depends on geometry through the view factor F_ij — the fraction of radiation leaving surface i that reaches surface j.
Reciprocity: A_i F_ij = A_j F_ji
Summation: Σ F_ij = 1
For common geometries, F values are tabulated:
- Two parallel plates: F = 1 for infinite plates
- Small object in large enclosure: F = 1 (all emission reaches enclosure)
- Two perpendicular plates: F ≈ 0.2
Radiation Exchange Between Surfaces
For two gray diffuse surfaces forming an enclosure:
q_12 = σ × (T₁⁴ - T₂⁴) / [(1-ε₁)/(ε₁A₁) + 1/(A₁F₁₂) + (1-ε₂)/(ε₂A₂)]
This is the general formula. For common cases, simplifications exist:
Small object in large enclosure:
q = ε × σ × A × (T_s⁴ - T_surr⁴)
Combined Convection and Radiation
Real surfaces lose heat by both convection and radiation. Add the two:
q_total = h_conv × A × (T_s - T_air) + ε × σ × A × (T_s⁴ - T_surr⁴)
For small ΔT, linearize radiation:
h_r = 4 × ε × σ × T_m³
So total h = h_conv + h_r. At room temperature, h_r ≈ 6 W/m²·K for ε = 1.
Radiation Shields
To reduce radiation, insert a low-emissivity shield between surfaces. Each shield reduces heat transfer.
For N shields between two surfaces:
q_with_shields / q_without = 1 / (N + 1)
This is how multi-layer insulation (MLI) works in spacecraft — many aluminized Mylar layers reduce radiative heat loss dramatically.
Key Takeaways
- All objects radiate; blackbodies are ideal emitters
- Stefan-Boltzmann: E = εσT⁴
- Wien's law: peak wavelength = 2898/T
- Kirchhoff: α = ε (good absorbers are good emitters)
- View factors describe geometric exchange
- Radiation shields reduce heat transfer
- At room temperature, radiation ≈ convection (h_r ≈ 6)
- At high temperature, radiation dominates (T⁴)
Heat Exchangers
What is a Heat Exchanger? A device that transfers heat between two fluids without mixing them. Everywhere: Car radiators Air conditioners Power plant condensers Chemical plant preheaters Computer C...
What is a Heat Exchanger?
A device that transfers heat between two fluids without mixing them. Everywhere:
- Car radiators
- Air conditioners
- Power plant condensers
- Chemical plant preheaters
- Computer CPU coolers
- Refrigerators
Classification
By flow arrangement:
- Parallel flow: both fluids enter at the same end, flow in the same direction
- Counterflow: fluids enter at opposite ends, flow in opposite directions
- Crossflow: fluids flow perpendicular to each other
- Shell and tube: one fluid in tubes, one in the shell
By construction:
- Tubular: concentric tubes, shell-and-tube, spiral
- Plate: flat plates stacked, compact
- Extended surface: finned tubes (for gas-liquid)
The Overall Heat Transfer Coefficient
Q = U × A × ΔT_lm
where:
- Q = heat duty (W)
- U = overall heat transfer coefficient
- A = heat transfer area
- ΔT_lm = log mean temperature difference
U depends on the individual resistances:
1/UA = 1/(h_i A_i) + R_wall + 1/(h_o A_o)
where i and o refer to inner and outer surfaces.
Typical U values:
- Water-to-water: 800-1500 W/m²·K
- Water-to-air (finned): 25-100
- Steam-to-water: 1000-3000
- Gas-to-gas: 10-50
Log Mean Temperature Difference
For counterflow or parallel flow:
ΔT_lm = (ΔT₁ - ΔT₂) / ln(ΔT₁/ΔT₂)
where ΔT₁ and ΔT₂ are the temperature differences at the two ends.
Counterflow gives higher ΔT_lm than parallel flow for the same inlet/outlet temperatures → smaller heat exchanger for the same duty.
Counterflow vs Parallel
Consider hot fluid cooling from 100°C to 60°C, cold fluid heating from 20°C to 50°C.
Parallel flow:
- ΔT₁ = 100 - 20 = 80°C
- ΔT₂ = 60 - 50 = 10°C
- ΔT_lm = (80-10)/ln(8) = 43.3°C
Counterflow:
- ΔT₁ = 100 - 50 = 50°C
- ΔT₂ = 60 - 20 = 40°C
- ΔT_lm = (50-40)/ln(1.25) = 44.8°C
Similar in this case, but counterflow can achieve much more when the hot outlet would be lower than the cold outlet.
Effectiveness-NTU Method
When outlet temperatures are unknown (they depend on the heat exchanger), the LMTD method requires iteration. The effectiveness-NTU method avoids this.
Effectiveness (ε):
ε = Q_actual / Q_max
where Q_max = C_min × (T_h,in - T_c,in).
C_min is the smaller of C_h = m_h × Cp_h and C_c = m_c × Cp_c.
NTU (Number of Transfer Units):
NTU = U × A / C_min
For each flow arrangement, there's a relation between ε and NTU:
Parallel flow:
ε = [1 - exp(-NTU(1 + Cr))] / (1 + Cr)
Counterflow:
ε = [1 - exp(-NTU(1 - Cr))] / [1 - Cr × exp(-NTU(1 - Cr))]
where Cr = C_min / C_max.
For Cr = 1 counterflow: ε = NTU / (1 + NTU).
Design Procedure
- Compute heat duty Q = m_h × Cp_h × (T_h,in - T_h,out)
- Compute C_min, C_max, Cr
- Compute Q_max = C_min × (T_h,in - T_c,in)
- Required ε = Q / Q_max
- From ε-NTU relation, find NTU
- A = NTU × C_min / U
Fouling
Over time, deposits on heat transfer surfaces add resistance. Fouling factors R_f are added to the U calculation:
1/U_dirty = 1/U_clean + R_f,i + R_f,o
Typical fouling factors: 0.0001-0.001 m²·K/W.
Fouling is often the dominant resistance after months of operation. Regular cleaning (chemical or mechanical) is essential.
Key Takeaways
- Heat exchangers transfer heat between fluids
- Counterflow is more efficient than parallel flow
- LMTD method: Q = UA ΔT_lm
- ε-NTU method when outlet temps are unknown
- U depends on both fluid-side resistances
- Fouling adds resistance over time
- Compact heat exchangers use fins for gas-side enhancement
📝 Problem Set 1: Conduction, Convection, Radiation
Q1. A wall 0.2 m thick with k = 0.8 W/m·K has inner surface at 25°C and outer at 5°C. Find heat flux.
Show Solution
q/A = kΔT/L = 0.8 × 20 / 0.2 = 80 W/m².
Q2. A surface at 100°C loses heat by natural convection to air at 20°C (h = 10 W/m²·K) and radiation (ε = 0.9). Find total heat flux.
Show Solution
q_conv = 10 × 80 = 800 W/m². q_rad = 0.9 × 5.67e-8 × (373⁴ - 293⁴) = 0.9 × 5.67e-8 × (1.936e10 - 7.37e9) = 0.9 × 5.67e-8 × 1.199e10 = 612 W/m². Total = 1412 W/m².
Q3. A fin has efficiency 0.7 and area 0.01 m². Base is at 80°C, ambient 25°C, h = 20 W/m²·K. Find heat transfer from the fin.
Show Solution
q = 0.7 × 20 × 0.01 × 55 = 7.7 W.
🎯 Midterm 1: Conduction, Convection, Radiation, HX
Q1. A composite wall has two layers: 5 cm of brick (k=0.7) and 10 cm of insulation (k=0.04). Total ΔT = 30°C over 1 m². Find the heat rate.
Show Solution
R_brick = 0.05/0.7 = 0.0714 K/W. R_insul = 0.1/0.04 = 2.5 K/W. R_total = 2.571 K/W. q = 30/2.571 = 11.7 W.
Q2. A CPU dissipates 65 W. Heatsink has R_sa = 0.3 K/W, paste R_cs = 0.1 K/W. Ambient 25°C. Find the CPU case temperature.
Show Solution
T_case = 25 + 65 × (0.3 + 0.1) = 25 + 26 = 51°C.
Q3. A counterflow heat exchanger has U = 500 W/m²·K, A = 2 m². Hot fluid: 90°C in, 60°C out. Cold: 20°C in, 40°C out. Find heat duty.
Show Solution